• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Power Electronic Tips

Power Electronic News, Editorial, Video and Resources

  • Products
    • Power Supplies
    • AC-DC
    • DC-DC
    • MOSFETS
    • Power Management
    • Battery Management
    • RF Power
    • Resistors
    • Capacitors
    • Magnetics
    • Transformers
  • Applications
    • LED Lighting
    • Rack Mount
    • Wireless
  • EE Forums
    • EDABoard.com
    • Electro-Tech-Online.com
  • EE Learning Center
    • Design Guides
      • WiFi & the IOT Design Guide
      • Microcontrollers Design Guide
      • State of the Art Inductors Design Guide
  • Video
    • EE Videos
    • TI Power Videos
    • Teardown Videos
  • Resources
    • Design Fast
    • eBooks / Tech Tips
    • FAQ
    • LEAP Awards
    • Podcasts
    • Webinars
    • White Papers

Don’t be confused by line and neutral fusing

October 17, 2019 By Lee Teschler Leave a Comment

It pays to know when the use of a single fuse is less hazardous than fusing both hot and neutral wires.

David Norton | TDK-Lambda Americas
For many years ac-dc power supplies for the medical market have been safety certified to the IEC 60601-1 medical standard and to the industrial IEC 60950-1 /IEC 62368-1 standards. Dual certification reduces the number of individual model numbers manufacturers must produce and stock.

dual fusingA point to note is that two ac input fuses are needed in many medical applications, one in the Line side and one in the Neutral side. Dual fusing is necessary to guarantee full protection if the polarity of the Line and Neutral wiring to the power supply should be reversed. This condition might arise due to a wiring error at the building’s ac socket or in the wiring feeding the power supply.

Nevertheless, supply manufacturers such as TDK-Lambda now offer a single (Line) fuse option on new medical/industrial power supplies. Here is the explanation why:

If an industrial system is consuming more current than a regular ac socket can support, it would have to be permanently connected to a distribution panel or building wiring. This task is normally carried out by a professional electrician, who would be aware of the potential dangers of a polarity reversal.

In the event of an over-current fault in the power supply or fuse aging, there is a 50% chance that either the Line or Neutral fuse would open. If the Neutral fuse was to open, a service technician may believe that there is no ac power applied to the power supply. Inadvertent contact with the Line while touching the earth ground would result in an electrical shock. This is even more likely if the power supply in question is of an open frame type construction.

To avoid this possibility, the NEC, CEC, IEE Wiring Regulations and IEC 364 specifically prohibit fusing in the Neutral in this type of equipment. To comply, a single-fuse power supply must be selected. The candidates are typically industrial (single fuse) or medical/industrial power supplies with a single-fuse option.

This scenario brings up the question of whether there are cases where an external fuse should go in the neutral connection of an industrial DIN rail power supply. DIN rail power supplies are rarely certified to medical safety standards. Usually they only have a single input fuse.

phase-to-phase vectors
phase to phase connectionConsider the case where the application is a power supply operating phase-to-phase from a three-phase WYE configuration in North America. Connecting phase-to-phase enables the equipment to be supplied with 208-Vac which draws less input current than using 115 Vac. This configuration allows the use of smaller wire gauges and connectors which saves money and are easier to install.

In the UL safety report Conditions of Acceptability, or Technical Considerations section, reference is made to all testing being performed on a protected branch circuit rated for 20 A; this section also lists the items that a user should consider before applying power to the unit.

If a short or overload inside the power supply happens across the Line-and-Neutral or Line-and-Ground, an internal fuse will open. If the short happens from Neutral-to-Ground, the fuse or breaker at the distribution panel will open.

external neutral fuseIf, however, the equipment connection to the building installation wiring is made via a non-industrial plug and socket, then an external fuse or breaker must be added in the Neutral line. This applies to input voltages of less than 240 Vac +10%.

It is best to always have your equipment installed by a qualified electrician and checked by a safety engineer for compliance to the relevant building and electrical codes!

You may also like:

  • top power electronics edaboard september
    Power Electronics Top Talks in September 2019 on EDABoard.com
  • peltier modules
    How to design a Peltier module system
  • analog devices
    How bidirectional converters speed the design of dual-battery automotive systems
  • low-power checks
    Understanding low-power checks and how to use them

Filed Under: FAQ, Featured, Power Supplies Tagged With: tdklambdacorporation

Reader Interactions

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Primary Sidebar

CURRENT DIGITAL ISSUE

A frequency you can count on There are few constants in life, but what few there are might include death, taxes, and a U.S. grid frequency that doesn’t vary by more than ±0.5 Hz. However, the certainty of the grid frequency is coming into question, thanks to the rising percentage of renewable energy sources that…

More from the digital archive

DesignFast

Component Selection Made Simple.

Try it Today
design fast globle

Subscribe to our Newsletter

The Power Electronic eNewsletter delivers breaking electronic and power component news, resources, product innovations and more.

Subscribe today

EE TRAINING CENTER CLASSROOMS

EE Classrooms

RSS Current EDABoard.com discussions

  • DC DC converter output voltage rise time
  • SMPS topology
  • LLC HB with synchronous rectifiers can be very dodgy?
  • Reducing switching noise in MOSFET inverter
  • Mathematical formula that converts voltage to weight the HX711 is using

RSS Current Electro-Tech-Online.com Discussions

  • Are Cross-wind compensation and Road crown compensation functions inputs to LKA function?
  • 500+V power supply from 9V battery using ZVS
  • IRFP450A replacement with IRFP460N on SIEG X2/LTF058213220 mini drill SIEG-FC350SMD Board
  • Sears Model 10656 Clock Radio - Clock board demanding high wattage resistor?
  • Trying to make a custom automated water container for my UV purifier. Can anyone help with where to begin?

Footer

EE World Online Network

  • DesignFast
  • EE World Online
  • EDA Board Forums
  • Electro Tech Online Forums
  • Connector Tips
  • Microcontroller Tips
  • Analog IC Tips
  • Sensor Tips
  • Test and Measurement Tips
  • Wire and Cable Tips
  • 5G Technology World

Power Electronic Tips

  • Subscribe to our newsletter
  • Advertise with us
  • Contact us
  • About us
Follow us on TwitterAdd us on FacebookFollow us on YouTube Follow us on Instagram

Copyright © 2022 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy